Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Contact Now
Knkong Electric Co.,Ltd
City:zhengzhou
Province/State:henan
Country/Region:china
Contact Person:MrKen Chan (English)
Contact Now

Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Ask Latest Price
Video Channel
Brand Name :KNKONG
Model Number :VS1-12
Certification :CB,ISO,IEC
Place of Origin :China
MOQ :1
Price :USD 1000-2000 Each
Payment Terms :L/C, T/T, Western Union
Supply Ability :1000 Unit per month
Delivery Time :15 working days
Packaging Details :Standard export packaging
Voltage :12KV
Current :630A
Breaking current :25KA
Type :Fixed
Original :China
Manufactory :KNKONG
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

VS1-12 fixed type 205 phase spacing Vacuum Circuit Breaker 12KV 630A

Voltage: 12KV

Current: 630A

Breaking current: 20KA

Type: Fixed

Product overview

VS1-Series circuit breakers are complete independently developed by Knkong based on the advanced design concept; it adopts a modularized mechanism, which is easy for installation, maintenance, testing, and operation. As compared with conventional VS1 circuit breaker. it features higher operation stability, higher safety, and extended service life. The product can satisfy customers demand application in 12kv and 24kV power transmission and distribution systems, which is extensively applied in such industries as power, energy, petrochemical engineering, metallurgy, manufacture, traffic, building, and environmental protection as well as large-scale enterprises and national key projects

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

Rated insulation level

1min power frequency withstand voltage(r. m. s)

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

4

Rated current

A

630 630 1250 1600
1250 1250 1600 2000
2000 2500
2500 3150
4000
5 Rated short-circuit breaking current

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit s 4
10 Rated operating sequence O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

≤100
24 Breaking time ≤50

25

Resistance of each phase main circuit

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

27

Rated operating voltage Rated operating voltage(V)AC/DC

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220,DC110/220
29 Energy storage time S ≤15

Operation safety

The circuit breaker has anti-mis-lock protection and "5 guarantees" interlocking function to avoid misoperation and protect the personal safety of operators to the greatest extent.
Only when the circuit breaker and the grounding switch are in the off position, the circuit breaker cart can roll from the test position to the service position
The circuit breaker can only be closed in the service/test position.
After the circuit breaker is closed, the truck cannot be rolled in or out, only when the circuit breaker is in the open position.
The circuit breaker cannot be rolled out from the service position to the test position in the closed position.
The circuit breaker cannot be closed when pushed in.
When the circuit breaker is closed, if the closing signal is not released in time, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).
If electric closing and locking is selected, when the secondary circuit cannot provide power or the power provided cannot satisfy the normal operation of the locking electromagnet (optional), the circuit breaker will not be closed.