Transformer technical parameters table
Product Description
Main technical parameter
Preassembled substation technical parameter table
| Serial number |
Name |
Unit |
Technical specification |
| 1 |
rated voltage |
KV |
10/0.4(high voltage/low voltage) |
| 2 |
maximum working voltage |
KV |
12(high-pressure side) |
| 3 |
rated frequency |
HZ |
50 |
| 4 |
rated capacity |
KVA |
50-1600 |
| 5 |
1-minute power frequency withstand voltage |
KV |
35 |
| 6 |
lightning impulse voltage |
KV |
75 |
| 7 |
type of cooling |
|
Oil immersed in self-cooling |
| 8 |
High voltage backup fuse breaking current |
KA |
50 |
| 9 |
Breaking the current of the plug-in fuse |
KA |
2.5 |
| 10 |
environment temperature |
ºC |
-35~+40 |
| 11 |
Coil allowable temperature rise |
ºC |
65 |
| 12 |
No load voltage regulation |
|
±5%or±2x2.5% |
| 13 |
noise grade |
db |
50 |
| 14 |
level of protection |
|
IP43 |
Transformer technical parameters table
Selection of new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are anti-loose treatment, no lifting core; S10 series and S11 series transformers with better performance are also available.
| Capacity kva |
Voltage |
no-load current |
open circuit losses |
impedance voltage |
load loss |
| high voltage |
low voltage |
S9 |
S10 |
S11 |
S9 |
S10 |
S11 |
4.0 |
S9 |
S10 |
S11 |
| 50 |
10±5% ±2x2.5% |
0.4 |
2.0 |
1.9 |
0.75 |
0.17 |
0.15 |
0.12 |
0.87 |
0.83 |
0.87 |
| 63 |
1.9 |
1.8 |
0.7 |
0.2 |
0.18 |
0.14 |
1.04 |
0.99 |
1.04 |
| 80 |
1.9 |
1.7 |
0.7 |
0.25 |
0.22 |
0.175 |
1.25 |
1.2 |
1.25 |
| 100 |
1.8 |
1.55 |
0.65 |
0.29 |
0.26 |
0.2 |
1.5 |
1.42 |
1.5 |
| 125 |
1.7 |
1.45 |
0.65 |
0.34 |
0.3 |
0.235 |
1.8 |
1.72 |
1.8 |
| 160 |
1.6 |
1.3 |
0.6 |
0.4 |
0.36 |
0.27 |
2.2 |
2.12 |
2.2 |
| 200 |
1.5 |
1.2 |
0.55 |
0.48 |
0.43 |
0.33 |
2.6 |
2.5 |
2.6 |
| 250 |
1.4 |
1.1 |
0.5 |
0.56 |
0.5 |
0.39 |
3.05 |
2.9 |
3.05 |
| 315 |
1.4 |
1.0 |
0.45 |
0.67 |
0.29 |
0.465 |
3.65 |
3.45 |
3.65 |
| 400 |
1.3 |
1.0 |
0.4 |
0.8 |
0.71 |
0.56 |
4.3 |
4.15 |
4.3 |
| 500 |
1.2 |
1.0 |
0.4 |
0.96 |
0.85 |
0.67 |
5.15 |
4.82 |
5.15 |
| 630 |
1.1 |
0.8 |
0.4 |
1.2 |
1.6 |
0.81 |
4.5 |
6.2 |
5.86 |
6.2 |
| 800 |
1.0 |
0.7 |
0.35 |
1.4 |
1.23 |
0.98 |
7.5 |
7.2 |
7.5 |
| 1000 |
1.0 |
0.6 |
0.3 |
1.7 |
1.5 |
1.15 |
10.3 |
9.8 |
10.3 |
| 1250 |
0.9 |
0.6 |
0.27 |
1.95 |
1.72 |
1.36 |
12.0 |
12.2 |
12.0 |
main technical parametersLoad switch technical parameter table
The load switch is an oil-immersed, three-phase linkage switch with, spring operating mechanism; It can be operated with load division and brake, and its division and speed have nothing to do with the size of the operating force. There are two stations, four stations T-type, four stations V-type, and so on.
| Serial number |
Name |
Unit |
Four-station loop load switch |
Two-station load switch |
| 1 |
rated voltage |
A |
630 |
315 |
| 2 |
Rated short-circuit closing current |
KA |
31.5 |
31.5 |
| 3 |
rated short-time current |
KA |
12.5 |
12.5 |
| 4 |
Rated short endurance time |
S |
2 |
2 |
| 5 |
mechanical life |
Next |
2000 |
2000 |
| 6 |
Lightning impulse withstand voltage peak full wave |
Phase to phase |
KV |
75 |
75 |
| 7 |
isolating fracture |
|
85 |
85 |
| 8 |
1min power frequency withstand voltage |
Phase to phase |
KV |
42 |
42 |
| 9 |
isolating fracture |
|
48 |
48 |
| 10 |
Rated peak withstand current |
KA |
31.5 |
31.5 |
Fuse technical parameters(The company oil oil-immersed fuse selection configuration recommendation table)
| Serial number |
Three-phase transformer capacity(KVA) |
XRNT rated current(A) |
PRNT1 Overload protection rated current(A) |
| 1 |
30 |
10 |
6 |
| 2 |
50 |
16 |
8 |
| 3 |
80 |
16 |
10 |
| 4 |
100 |
20 |
15 |
| 5 |
125 |
25 |
15 |
| 6 |
160 |
31.5 |
25 |
| 7 |
200 |
40 |
25 |
| 8 |
250 |
50 |
40 |
| 9 |
315 |
63 |
40 |
| 10 |
400 |
63 |
40 |
| 11 |
500 |
80 |
50 |
| 12 |
630 |
100 |
50/65 |
| 13 |
800 |
125 |
65 |
| 14 |
1250 |
160 |
100 |
| 15 |
1600 |
200 |
140 |